A vented vial adapter for reconstitution of a medicament in a vial includes a vent lumen and a medicament lumen. The vent lumen has a cross-sectional area equal to or greater than that of the medicament lumen so that the fluid flow rate through the vent lumen is equal to or greater than that of the medicament lumen. As a result aerosols of the medicament outside the adapter are avoided as is
· Place the OBIZUR vial on a clean, flat, hard surface. Place the vial adapter over the OBIZUR vial and firmly push the filter spike of the vial adapter through the center of the OBIZUR vial's rubber circle until the clear plastic cap snaps onto the vial (Figure F).
· The Vialok Vented Vial Access Device (VVAD) is designed for ease of use on a variety of vials. The devices include a 0.2µm hydrophobic air-venting filter that neutralizes vial pressure, minimizing aerosols and surface contamination. The VVAD vial spike does not core the stopper during attachment, precluding cored fragments from coming loose.
Closed Vial Adaptor. Halo’s Closed Vial Adaptors are intended for closed preparation of drugs. The system is compatible with standard vials with 13mm, 20mm, and 28mm OD necks, which correspond to CVA130, CVA200, and CVA280 respectively.
We are a global supplier of plastic medical components. Stock and custom components, full design, manufacturing, multilingual support. Order samples now.
· the green vial adapter cap Attach the MAD Nasal Device to the syringe via the luer lock connector Pierce the medication vial with the syringe vial adapter Aspirate the proper volume of medication required to treat the patient (including medication to account for the dead space in the device) User Guide Procedure Remove (twist off) the syringe from
· CH-62 ChemoClave Vial Spike, 13 mm 50 ChemoClave Vented Vial Spikes A 0.22 micron hydrophobic filter automatically equalizes vial pressure. Allows access to vials with 13 mm, 20 mm, and 28 mm closures. Item Description Case Qty Product Image CH-70 ChemoClave Universal Vented Vial Spike, 20 mm and 28 mm 50 CH-70-5 ChemoClave Universal Vented
· 4 ®Open the Mix2Vial filter transfer set by peeling off the lid. Do not remove the transfer set from the blister package. 5 Place the Sterile Water for Injection vial on an even, clean surface and hold the vial tight. Take the transfer set together with the blister package and push the spike of the blue adapter end straight down through
· CH-62 ChemoClave Vial Spike, 13 mm 50 ChemoClave Vented Vial Spikes A 0.22 micron hydrophobic filter automatically equalizes vial pressure. Allows access to vials with 13 mm, 20 mm, and 28 mm closures. Item Description Case Qty Product Image CH-70 ChemoClave Universal Vented Vial Spike, 20 mm and 28 mm 50 CH-70-5 ChemoClave Universal Vented
· 2.1 Dose. Each vial of IXINITY has the recombinant factor IX (rFIX) potency in international units (IU) stated on the vial. Dosage and duration of treatment for factor IX products depend on the severity of the factor IX deficiency, the location and extent of bleeding, the patient’s clinical condition, age, and pharmacokinetic parameters of factor IX, such as incremental recovery and half-life.
Vial adapters are a cost-effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth. for drug and diluent aspiration, which greatly reduces the end-user variability associated with traditional needle aspirations and helps
Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager? 800.422.0280. Accounts Receivable 800.453.5180
· For closed reconstitution and withdrawal of medications with most 20 mm and 13 mm vials (with vial converter ring provided) Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste, help make implementations easier and reduce confusion. Just compound and go. No need to pre-prime or pre-activate the vial adaptor.
Vial Adapter ICU Medical CH-51. Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager?
PINSYNC ®. PINSYNC ® is a vented vial adapter for use with DEFINITY ® as an alternative to needles. It is intended for use with activated DEFINITY ® Vial for (Perflutren Lipid Microsphere) Injectable Suspension only.. It offers safe and rapid DEFINITY ® transfer from vial to syringe.. Simple, safe, and rapid DEFINITY ® transfer Self-venting design
Small vial adapter with vented Material Filter (PALL) ABS PP (cap) Can help the medical staff avoid drug infection. (See in Pic 3) And we can glue Gen2 needleless connector on it. Or assemble the CA-016 on it. (See in Pic 2) Picture location
· CH-62 ChemoClave Vial Spike, 13 mm 50 ChemoClave Vented Vial Spikes A 0.22 micron hydrophobic filter automatically equalizes vial pressure. Allows access to vials with 13 mm, 20 mm, and 28 mm closures. Item Description Case Qty Product Image CH-70 ChemoClave Universal Vented Vial Spike, 20 mm and 28 mm 50 CH-70-5 ChemoClave Universal Vented
· Tevadaptor Vial Adaptorfor closed reconstitution and withdrawal of medications with most 20 mm and 13mm vials (with vial converter ring provided). Components do not contain DEHP or natural rubber latex. 50/box, 4 boxes/case 412111 412111 200 Tevadaptor Vial Adaptor for 28 mm vials Components do not contain DEHP or natural rubber latex.
· Vented vial access devices can be used on a variety of vials. They feature a .2 micron filter that minimizes aerosols and surface contamination while neutralizing vial pressure. Non-vented vial access devices are a great choice for use on small, low volume vials. Vented vial access devices available in universal, 13mm, 20mm, and 28mm sizes.
Primary Sapphire™ Epidural Set, Microbore, Yellow-Striped Tubing, 0.2 Micron Filter, NRFit™ Connector, 119 Inch 119" / 302.26 cm 0.054
ICU Medical's newest product line is the ChemoLock, consisting of a needleless membrane-based connector, metalized external expansion chamber, and reinforced vial spike. As with all membrane-based devices, a luer adapter is required.
Number of Y-Sites. Product Image. . Multi-Dose Vial Adapter. 2" / 5.08 cm. . Two-Way Transfer Device.
Vial Adapter — with 0.22 micron vent and Clave™ connector. Product Numbers List Number shop.icumed Number EDI Number Filtered No Sterile Pack No Hand Pump No Backcheck Valve No Latex Information Natural rubber latex has not been used in the manufacture of this product Case Information Order Quantity 1 Case (50) Case Size 1 x 50 Cases per Tier 36 Cases per
The 3M™ Filter Adapter 603 enables the 5N11 and 5P71 N95 and P95 prefilters to be directly attached to a 3M™ Full or Half Facepiece 6000, 6500, 7000 or FF-400 Series or 3M™ Scott™ AV-3000 HT and AV-3000 SureSeal facepieces with 3M™ Scott™ AV-632 Bayonet Adapter. Do not use the filter adapter 603 with the 650XQL Series half facepiece.
Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager? 800.422.0280. Accounts Receivable 800.453.5180
Assembling the filter and adapter components is simple and easy. To add a filter (2) to the Easy on-PC, insert the Spirette normally. Then attach the (1) filter adapter (SP) to the back of the spirette and connect the filter to filter adapter (SP), as shown in the diagram below.
· OnGuard® Vial Adaptor. Benefits of OnGuard ® CSTD Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste, help make implementations easier and reduce confusion. Just compound and go. No need to pre-prime or pre-activate the vial adaptor. Click to lock. No push and twist. Linear connection designed to
· • Filter the reconstituted product to remove potential particulate matter in the solution. Filtering is achieved by using the vial adapter. 1. Warm both unopened KOVALTRY vial and prefilled diluent syringe in your hands to a comfortable temperature (do not exceed 37°C or 99°F). 2. Remove the protective cap from the vial (A).